Marina Power Company
Menu
  • External link opens in new tab or window
  • External link opens in new tab or window
  • External link opens in new tab or window305.470.0037
  • External link opens in new tab or windowinfo@marinapower.net
  • External link opens in new tab or windowFacebook
  • External link opens in new tab or windowInstagram

 

Column

Power Centers

POWER CENTERS

Column

Power Modules & Substations

POWER MODULES &

SUBSTATIONS

Column

Light Bollards

LIGHT BOLLARDS

Column

Fire Equipment

FIRE EQUIPMENT

Power Modules & Substations

Custom Power Modules & Substations



Column


Combination Power Modules

SPECIFICATIONS:

  • 5052 Marine grade aluminum or stainless steel
  • .125 Gauge aluminum or 14 gauge 304 stainless
  • Powder Coated Gloss Sky White
  • Other colors available upon request
  • Height 48”
  • Width 60”
  • Depth 36”
  • All hardware stainless steel
  • Unit listed Nema 3R

FEATURES:

  • The above unit is assembled and is used predominately on marinas for stepping 480 volt down to 120/240 and/or 120/208 three-phase.
  • All Combination Power Modules utilize 25 kva transformers.
  • All breakers are Siemens and all Receptacles are Hubbell or Cooper ArrowHart.
  • Unit is listed as an assembly by Intertek Testing Services (ETL) to UL231 Standard.
  • Electric meters are by EML Associates and carry a 2 year warranty.
  • Provided with four cooling fans.
  • Breakers and receptacles located under doors and provide with LED lighting.

Model PM32-FF480-FF120/208-EDD-EDD(120/240)-1M480-

1M208-2M240-CHT (shown)

Column

Substations

SPECIFICATIONS:

  • 5052 Marine grade aluminum or stainless steel
  • .125 Gauge
  • Powder Coated Gloss Sky White
  • Other colors available upon request
  • Maximum Height 84”
  • Maximum Width 72”
  • Maximum Depth 48”
  • Minimum Height 48”
  • Minimum Width 48”
  • Minimum Depth 24”
  • All stainless steel hardware


AVAILABLE MODELS
PM1PM2PM3PM4PM5
PM6PM21PM22PM31PM32
PM33PM211PM311PM3111 


FEATURES:

  • Above units convert 480 volt single or three-phase to 120/240 volt single or 120/208 volt three-phase.
  • These units are provided with loop feed lugs and primary circuit breakers if required. Secondary branch circuit breakers are also provided with or without main circuit breaker if required. Above units with five
  • or six 25 Kva epoxy encapsulated transformers or a combination of multiple transformers.
  • Unit is listed to UL50 Standard by Intertek Testing Services (ETL).
  • Unit is listed to UL231 Standard by Intertek Testing Services (ETL) and wired complete as an assembly.
  • Unit dimensions vary depending on components.
  • All breakers used are Siemens.
  • Transformers are Jefferson or Olsun Dry Type.
  • Weight varies from 1500 to 2000 lbs., depending on unit supplied.

Column

Switchgear Cabinets

SPECIFICATIONS:

  • 5052 Marine grade aluminum or stainless steel
  • .125 Gauge aluminum or 14 gauge 304 stainless
  • Powder Coated Gloss Sky White
  • Other colors available upon request
  • Height 72” or 84”
  • Width 48”
  • Depth 24 or 36”
  • Free Standing
  • Open bottom
  • Listed Nema 3R to UL50 Standard
  • Furnished with Siemens gear as required


Marina Power, 8456 Northwest 61st Street, Miami, FL 33166

 

External link opens in new tab or window

305.470.0037  |  info@marinapower.net

  • External link opens in new tab or windowFacebook
  • External link opens in new tab or windowInstagram
  • Home
  • Products
  • Valued Clients
  • Gallery
close lightbox